Fuse switch disconnectors
Fuse sizes from 10A to 400A
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DZ 2x63A
For 4-conductor IP20 busbar system
KSE and Trilite® P
1-Pole/ 3-poles with handle
AC-23B
10A-63A
DZ II / DZ III
63A
500V
DZ 2x63A-NR
For 3-conductor IP20 busbar system
KSE-NR
1-Pole/ 3-poles with handle
AC-23B
10A-63A
DZ II / DZ III
63A
500V
DIN00
For 4-conductor IP20 busbar system
KSE and Trilite® P
3-poles
AC-23B
20A-160A
NH-00
160A
500V
DIN00-NR
For 3-conductor IP20 busbar system
KSE-NR
3-poles
AC-23B
20A-160A
NH-00
160A
500V
DIN2
For 4-conductor IP20 busbar system
KSE and Trilite® P
3-poles
AC-23B
35A-400A
NH-2
400A
500V
DIN2-NR
For 3-conductor IP20 busbar system
KSE-NR
3-poles
AC-23B
35A-400A
NH-2
400A
500V
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DZ 2x63A
For 4-conductor IP20 busbar system
KSE and Trilite® P
1-Pole/ 3-poles with handle
AC-23B
10A-63A
DZ II / DZ III
63A
500V
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DZ 2x63A-NR
For 3-conductor IP20 busbar system
KSE-NR
1-Pole/ 3-poles with handle
AC-23B
10A-63A
DZ II / DZ III
63A
500V
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DIN00
For 4-conductor IP20 busbar system
KSE and Trilite® P
3-poles
AC-23B
20A-160A
NH-00
160A
500V
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DIN00-NR
For 3-conductor IP20 busbar system
KSE-NR
3-poles
AC-23B
20A-160A
NH-00
160A
500V
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DIN2
For 4-conductor IP20 busbar system
KSE and Trilite® P
3-poles
AC-23B
35A-400A
NH-2
400A
500V
Name
Type
To be used along with
Breaking
Connection Category
Fuse sizes
Fuse types
Rated operating current, Ie
Rated operating voltage
DIN2-NR
For 3-conductor IP20 busbar system
KSE-NR
3-poles
AC-23B
35A-400A
NH-2
400A
500V
  • Integrated hook system and one-tool screwdriver enables simple and fast assembly
  • Each type of fuse switch needs a minimal width, which ensures that the cable distribution enclosures take up as little space as possible in the public space
  • Touch-safe solutions: IP20 busbar system and IP20 fuse gear equipment makes work under voltage safe
  • Proven and reliable - used in Scandinavia for more than 30 years
  • Tested and approved according to EN 60947-7-1 and -3, and may as such be used without further design verification in Triarca's Cable distribution enclosures and Combination Enclosures
More Than Enclosures
Value-creating solutions for power distribution and fiber networks
More Than Enclosures
Value-creating solutions for power distribution and fiber networks
More Than Enclosures
Value-creating solutions for power distribution and fiber networks
More Than Enclosures
Value-creating solutions for power distribution and fiber networks
More Than Enclosures
Value-creating solutions for power distribution and fiber networks
More Than Enclosures
Value-creating solutions for power distribution and fiber networks